Zaxcom Digital Wireless System User’s Manual_______________________________________Chapter 2
27
Transmitter Bootup Sequences
Standard Bootup Sequence (without any card inserted)
LOWER POWER MODE
IFB IS OFF 0
(OPTIONAL PAGE: Only appears if Low Power mode is fully enabled.)
PCB REVB BBBB
VER A-AAA (CC)
(PCB REVB – Indicates the printed-circuit board is revision “B”.)
(A–AAA – Indicates the currently installed firmware version.)
(BBBB – Programmable logic device revision code.
„0000‟=no timecode input „0150‟=timecode input available.)
(CC – Indicates which options are available:
00=none, 01=Record, 02=IFB, 03=IFB & Record.)
Optional pages
None or one of these
is displayed based on
Boot Up Mode page
{p.42}.
(Only appears if the unit is set to:
STANDBY.)
(Appears after you press the MENU key.)
(Only appears if the unit is set to:
REMOTE STANDBY.)
REMOTE STANDBY 0
^ + MENU = EXIT
(DDDDDDDD – Displays the “Name” entered in the Extended Menu.
The initial default is “SN:”, followed by the unit‟s serial number.)
(This page displays the Digital Signal Processor clock rate in MHz. The
typical value is 98MHz.)
(OPTIONAL PAGE: This statement indicates the Encryption Code
page {p.44} has a code. Verify the code matches the receiver‟s code.)
(OPTIONAL PAGE: This is a reminder that the Allow IFB Remote
Control page {p.43} is set to “Off”. Should it be off?
(This page indicates the Audio processor is starting.)
ZAXCOM VA-AAA
WWWWWW SN:ZZZZZ
(WWWWWW – Indicates what hardware is being initialized.)
(ZZZZZ – Indicates the unit‟s serial number.)
(Be aware, if you get either of these alerts,
the unit will not go into RECORD mode.)
(The outline of the battery symbol starts blinking when the voltage
reaches a low level.)
(This page appears, when the battery HAS to be changed.)
Table 2-7 Standard Bootup Sequence (without any card inserted)